(2) 定子额定电流I1N:

转子回路每相漏阻抗的折算值z2’:

z2’=r2’/sN+jx2’=0.4/0.04+j2.0=10+j2.0

=10.2∠11.310Ω

励磁阻抗zm为

zm=rm+jxm=4.6+j48=48.22∠84.530Ω

z2’与zm并联阻抗

z2’zm/(z2’+zm)=(10.2∠11.310Ω×48.22∠84.530Ω)/(10+j2+4.6+j48)

=491.84∠95.840Ω/52.09∠22.120Ω=8.75+j3.55Ω

总阻抗z

z=z1+z2’zm/(z2’+zm)=0.4+j2+8.75+j3.55=9.15+j5.55=10.70∠31.240Ω

设相电压U1=380∠00V为参考向量,则定子电流I1N为

I1N=U1/z=380/∠00/10.70∠31.240=35.5∠-31.240A

转子电流I2’为,根据

U1=-E1-I1z1,E1=E2’,E2’=I2’z2’

所以

I2’=(-U1+I1z1)/z2’=(-380∠00+35.5∠-31.240×(0.4+j2))/10.2∠11.310 =(-380+35.5∠-31.240Ω×(2.04∠78.690)/10.2∠11.310

=(-380+72.42∠47.450)/10.2∠11.310=(-380+48.97+j53.35)/10.2∠11.310 =(-331.03+j53.35)/10.2∠11.310=335.3∠170.840/10.2∠11.310 =32.87∠159.530A 励磁电流I0为

I0=(U1-I1z1)/zm=(380∠00-72.42∠47.45)/48.22∠84.530

=(380-48.97-j53.35)/48.22∠84.530=(331.03-j53.35)/48.22∠84.530 =335.3∠-9.160/48.53∠84.530 =6.95∠-93.690A

(3) cosφ1N

cosφ1N=cos31.240=0.855(滞后)

(4) 总损耗∑p 定子铜损耗pcu1

pcu1=3I1N2r1=3×35.52×0.4=1512.3W

转子铜损耗pcu1

pcu2=3I2’2r2’=3×32.872×0.4=1296.5W

铁损耗pFe

pFe=3I02rm=3×6.952×4.6=666.6W

总损耗∑p

∑p= pcu1+pcu2+pFe+pm+ps=1512.3+1269.5+666.6+300+100=3875.4W

(5) 额定输出功率P2N: 机械功率Pm:

Pm=3I2’2r2’(1-sN)/sN=3×32.872×0.4(1-0.04)/0.0431117W

P2N=Pm-pm-ps=31117-300-100=30717W

(6) 效率

- 17 -- 17 -

输入功率P1:

P1=3U1I1NcosΦ1N=3×380×35.5×0.855=34602W

效率η

η=1-∑p/P1=1-3875.4/34602=0.89

1.有一台笼形异步电动机,PN?20kW,IstIN?6.5,如果变压器容量为

SN?560kVA,问能否直接起动?(4分) 解:判断电机能否直接起动的依据是满足公式:

IQIN?3SN ?44PN3S3560?7.75 IQIN?6.5, ?N??44PN44?20所以满足上面的公式,此电动机可以直接起动。

2.并励电动机的UN=220V, IN=122A, Ra=0.15Ω, nN=960r/min。Rf=110Ω,如保持额定转矩不变,使转速下降到750 r/min,求需在电枢电路中串入电阻Rc的阻值?(8分) 解:串入电阻前:If?UN220??2A Ia?IN?If?122?2?110A Rf110 Ea?UN?IaRa?220?110?0.15?203.5V

EaCE?n'n'750'串入电阻调速后: 因此 Ea?159???V

EaCE?nNnN960由于额定转矩不变,Te?CT?Ia,所以Ia保持不变。

'U?Ea220?159??0.51? Ea?UN?IaRa 所以 Ra?NIa120''''Rc?Ra?Ra?0.51?0.15?0.36?

3.已知一台三相异步电动机的额定数据如下:

'PN=4.5KW,nN=950r/min,?N=84.5%,cos?N=0.8,起动电流与云额定电流之比Ist/IN=5,?=2,起动转距与额定转距之比Tst/TN=1.4,额定电压220/380V,接法星/三角,f1=50Hz。求(1)磁极对数p;(2)额定转差率sN;(3)额定转

- 18 -- 18 -

距TN;(4)三角形联结和星形联结时的额定电流IN;(5)起动电流Ist;(6)起动转距Tst。(12分) 解:(1)n1?60f13000, 当p?1时,n1?3000r/min当p?2时,?ppn1?1500r/min

当p?3时,n1?100r0/min而 nN?950r/min, 所以取p?3,此时

n1?100r0/min (2)SN?Pn1?nN1000?9504500?45.2N?m ??0.05(3)TN?9.55N?9.55?nN950n11000(4)三角形联结时IN? 星形联结时IN?PN3UNcos?N?NPN??45003?380?0.8?0.84545003?220?0.8?0.845?10.1A

3UNcos?N?N?17.47A

(5)三角形联结时 IQ?5IN?5?10.1?50.5A

星形联结时 IQ?5IN?5?17.47?87.35A (6)TQ??TN?2?45.2?90.4N?m

1.一台三相变压器,SN=5000kVA,U1N/U2N=35/10.5kV,Y,d接法,求原、副方的额定电流。(6分) 解: I1N?SN5000?103??82.48A33U1N3?35?10 I2N?

SN?3U2N5000?103?274.9A33?10.5?10 2.一台异步电动机,额定电压为380V,在某一负载下运行时,测得输入功率为4 kW,线电流为10A,求这时电动机的功率因数?若输出功率为3.2 kW,问效率是多少?(8分) 解:(1)额定输入功率:

- 19 -- 19 -

?P3U1NI1Ncos?1N1N??cos?1N?P1N(4)效率: 33??PNP?3.2?10/4?10?80% 1N3U1NI1N?4?1033?380?10?0.6 3.已知他励电动机的励磁电压和电枢电压为220V,Ia=60A,n=1000r/min,Ra=0.25Ω,Rf=150Ω。求励磁电流、电枢电势和电磁转矩。(10分) 解:励磁电流:

If?UfRf?220?1.47A 150电枢电势:

Ea?U?IaRa?220?60?0.25?205V

电磁转矩:

U?IaRa220?60?0.25Ce????0.205n1000CT??9.55Ce??9.55?0.205?1.958 Tem?CT?Ia?1.958?60?117.47N?m

1 一台单相变压器SN?5000kVA,U1NU2N? 10/6.3kV,试求原、副方的额定电流。(6分)

解:I1NSN5000?103???500A 3U1N10?10 I2N

SN5000?103???793.65A 3U2N6.3?102、一台三相感应电动机,

PN?75KW,nN?975rmin,UN?3000V,IN?18.5A, cos??0.87,fN?50Hz.试问:(1) 电动机的极数是多少?

- 20 -- 20 -

(2) 额定负载下的转差率s是多少?额定负载下的效率?是多少?(9分) 解:(1)电动机的极数:2p?6

n1?nN1000?975??0.025 n11000(2)额定负载下的转差率:sN?(3)额定负载下的效率:

?N?

PN3UNINcos?N?75?1033?3000?18.5?0.87?9000

V,IN?207.5A,3、一台他励直流电动机,PN?40KW,UN?220Ra?0.067?。若电枢回路不串电阻直接起动,则起动电流为额定电流的几倍?

若将起动电流限制为1.5IN,求电枢回路应串入的电阻大小。(9分)

.6A?15.82IN 解:(1)Ist?UNRa?2200.067?3283(2)Rp?UN1.5IN?Ra?220(1.5?207.5)?0.067?0.64?

1、他励直流电动机的UN=220V,IN=207.5A,Ra=0.067Ω,试问:(1)直接起动

时的起动电流是额定电流的多少倍?(2)如限制起动电流为1.5IN,电枢回路应串入多大的电阻? 解:(1)直接起动的电流Ist=UN/Ra=220/0.067=3283.6A Ist/IN=3283.6/207.5=15.8

(2)Ist1=1.5×IN=1.5×207.5=311.25A=UN/(Ra+Rst) 由此可得:Rst=0.64Ω

2、一台三相笼型异步电动机的额定数据为:PN=125KW,Nn=1460r/min,UN=380V,Y联结,IN=230A,起动电流倍数ki=5.5,起动转矩倍数kst=1.1,过载能力λT=2.2,设供电变压器限制该电动机的最大起动电流为900A,问:(1)该电动机可否直接起动?(2)采用电抗器降压起动,起动电抗xst值应为多少?(3)串入(2)中的电抗器时能否半载起动? 解:(1)直接起动电流为:Ist=kiIN=5.5×230A=1265A>900A 所以不能采用直接起动。

(2)定子串电抗器后,起动电流限制为900A 则:α=Ist/I?st=1265/900=1.4

短路阻抗为:Zs=√rs2+xs2 =UN/√3 ×Ist=380/ √3×1265 =0.173Ω

所以rs=0.3Zs=0.3×0.173=0.052Ω

xs=√Zs2-rs2 =√0.1732-0.0522 0.165Ω